Citation Information :
Kesavarapu SR, Ninan MK, Gali YM. Ultrasound—Optic Nerve Sheath Diameter: A Tool for Assessment of Intracranial Pressure. J Acute Care 2024; 3 (3):184-186.
Optic nerve sheath diameter (ONSD) is a noninvasive, bedside tool for estimating intracranial pressure (ICP) in conditions such as traumatic brain injury, intracranial hypertension, and optic neuritis. It is risk free compared to conventional methods, avoiding radiation and infection risks. ONSD also aids in evaluating intraventricular shunts, lumbar puncture feasibility, and conditions like idiopathic intracranial hypertension, intracranial hypotension, and stroke progression. Using ultrasound, ONSD correlates significantly with ICP. Measurement involves imaging 3 mm posterior to the globe with a high-frequency linear probe, avoiding oblique views and artifacts. Both transverse and sagittal views are assessed, with color Doppler assisting in accuracy. Compared to computed tomography (CT), ultrasound is cost-effective, safer, and suitable for serial ICP monitoring. However, caution is needed in cases of globe rupture, requiring prior ophthalmology evaluation. ONSD is a reliable and accessible tool in neurocritical care.
Cannata G, Pezzato S, Esposito S, et al. Optic nerve sheath diameter ultrasound: a non-invasive approach to evaluate increased intracranial pressure in critically ill pediatric patients. Diagnostics (Basel) 2022;12(3). DOI: 10.3390/diagnostics12030767
Tayal VS, Neulander M, Norton HJ, et al. Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients. Ann Emerg Med 2007;49(4):508–514. DOI: 10.1016/j.annemergmed.2006.06.040
Betcher J, Becker TK, Stoyanoff P, et al. Military trainees can accurately measure optic nerve sheath diameter after a brief training session. Mil Med Res 2018;5(1):42. DOI: 10.1186/s40779-018-0189-y
Caffery TS, Perret JN, Musso MW, et al. Optic nerve sheath diameter and lumbar puncture opening pressure in nontrauma patients suspected of elevated intracranial pressure. Am J Emerg Med 2014;32(12):1513–1515. DOI: 10.1016/j.ajem.2014.09.014
Hassen GW, Al-Juboori M, Koppel B, et al. Real time optic nerve sheath diameter measurement during lumbar puncture. Am J Emerg Med 2018;36(4):736.e1. DOI: 10.1016/j.ajem.2018.01.037
Dağdelen K, Ekici M. Measuring optic nerve sheath diameter using ultrasonography in patients with idiopathic intracranial hypertension. Arq Neuropsiquiatr 2022;80(6):580–585. DOI: 10.1590/0004-282X-ANP-2021-0136
Korsbæk JJ, Hagen SM, Schytz HW, et al. Transorbital sonography: a non-invasive bedside screening tool for detection of pseudotumor cerebri syndrome. Cephalalgia 2022;42(11-12):1116–1126. DOI: 10.1177/03331024221094293
Hanafi MG, Verki MM, Parei SN. Ultrasonic assessment of optic nerve sheath to detect increased intracranial pressure. J Med Ultrasound 2019;27(2):69–74. DOI: 10.4103/JMU.JMU_54_18
Helmke K, Hansen HC. Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension II. Patient study. Pediatr Radiol 1996;26(10):706–710. DOI: 10.1007/BF01383384
Moretti R, Pizzi B. Ultrasonography of the optic nerve in neurocritically ill patients. Acta Anaesthesiol Scand 2011;55(6):644–652. DOI: 10.1111/j.1399-6576.2011.02432.x
Zhu S, Cheng C, Zhao D, et al. The clinical and prognostic values of optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in comatose patients with supratentorial lesions. BMC Neurol 2021;21(1):259. DOI: 10.1186/s12883-021-02285-7
Liu D, Kahn M. Measurement and relationship of subarachnoid pressure of the optic nerve to intracranial pressures in fresh cadavers. Am J Ophthalmol 1993;116(5):548–556. DOI: 10.1016/s0002-9394(14)73195-2
Jalayondeja T, Urasyanandana K. Correlations between optic nerve sheath diameters measured using computed tomography and elevated intracranial pressure levels. Interdiscip Neurosurg 2021;26:101328. DOI: 10.1111/j.1399-6576.2011.02432.x
Kilker BA, Holst JM, Hoffmann B. Bedside ocular ultrasound in the emergency department. Eur J Emerg Med 2014;21(4):246–253. DOI: 10.1097/MEJ.0000000000000070
Romagnuolo L, Tayal V, Tomaszewski C, et al. Optic nerve sheath diameter does not change with patient position. Am J Emerg Med 2005;23(5):686–688. DOI: 10.1016/j.ajem.2004.11.004
Kim SH, Kim HJ, Jung KT. Position does not affect the optic nerve sheath diameter during laparoscopy. Korean J Anesthesiol 2015;68(4):358–363. DOI: 10.4097/kjae.2015.68.4.358
Copetti R, Cattarossi L. Optic nerve ultrasound: artifacts and real images. Intensive Care Med 2009;35(8):1488–1489; author reply 1490–1491. DOI: 10.1007/s00134-009-1494-4
Kim DY, Kim SY, Hong DY, et al. Comparison of ultrasonography and computed tomography for measuring optic nerve sheath diameter for the detection of elevated intracranial pressure. Clin Neurol Neurosurg 2021;204:106609. DOI: 10.1016/j.clineuro.2021.106609
Ussahgij W, Toonpirom W, Munkong W, et al. Optic nerve sheath diameter cutoff point for detection of increased intracranial pressure in the emergency department. Open Access Maced J Med Sci 2020;8(B):62–65. DOI: 10.3889/oamjms.2020.3272